Messages Reference Guide

Detailed
Description
This message occurs if there are medium errors in the physical drives.
Recommended
Response Action
Replace the failed drives.
Category Storage
SubCategory VDR = Virtual Disk
Severity Severity 1 (Critical)
Trap/EventID 4353
LCD Message No LCD message display defined.
Initial Default. SNMP Alert;#LCD;#Remote System Log
Filter
Visibility
IPMI Alert SNMP
Alert
Email
Alert
LC Log LCD Power Off Power
Cycle
Reset
TRUE FALSE TRUE TRUE TRUE TRUE FALSE FALSE FALSE
VDR57
Message Background Initialization in
arg1
corrected medium error.
Arguments
arg1 =
VD Name
Detailed
Description
A disk media error was detected while the controller was completing a background task. A bad
disk block was identified. The disk block has been remapped.
Recommended
Response Action
Consider replacing the disk. If you receive this alert frequently, ensure to replace the disk. It is
recommended to routinely back up your data.
Category Storage
SubCategory VDR = Virtual Disk
Severity Severity 3 (Informational)
Trap/EventID 4355
LCD Message No LCD message display defined.
Initial Default. SNMP Alert;#LCD;#Remote System Log
Filter
Visibility
IPMI Alert SNMP
Alert
Email
Alert
LC Log LCD Power Off Power
Cycle
Reset
TRUE FALSE TRUE TRUE TRUE TRUE FALSE FALSE FALSE
VDR93
Message
arg1
bad block medium error is cleared.
Arguments
arg1 =
VD Name
888