Messages Reference Guide

Severity Severity 2 (Warning)
Trap/EventID 4354
LCD Message No LCD message display defined.
Initial Default. SNMP Alert;#LCD;#Remote System Log
Filter
Visibility
IPMI Alert SNMP
Alert
Email
Alert
LC Log LCD Power Off Power
Cycle
Reset
TRUE FALSE TRUE TRUE TRUE TRUE FALSE FALSE FALSE
VDR55
Message
arg1
initialization has failed.
Arguments
arg1 =
VD Name
Detailed
Description
The controller cannot communicate with attached devices. A disk may be removed or contain
errors. Cables may also be loose or defective.
Recommended
Response Action
Verify the health of attached devices. Review the Alert Log for significant events. Make sure
the cables are attached securely. See the Cables Attached Correctly section for more
information on checking the cables.
Category Storage
SubCategory VDR = Virtual Disk
Severity Severity 1 (Critical)
Trap/EventID 4353
LCD Message No LCD message display defined.
Initial Default. SNMP Alert;#LCD;#Remote System Log
Filter
Visibility
IPMI Alert SNMP
Alert
Email
Alert
LC Log LCD Power Off Power
Cycle
Reset
TRUE FALSE TRUE TRUE TRUE TRUE FALSE FALSE FALSE
VDR56
Message Redundancy of
arg1
has been degraded.
Arguments
arg1 =
virtual disk
Detailed
Description
This message occurs when a physical disk in the disk group was removed or when a physical
disk included in a redundant virtual disk fails. Because the virtual disk is redundant (uses
mirrored or parity information) and only one physical disk has failed, the virtual disk can be
rebuilt. Typically, the virtual disk (E.g. RAID 6) has multiple redundant disks and there is a
problem with one of them.
886