Messages Reference Guide

Filter
Visibility
IPMI Alert SNMP
Alert
Email
Alert
LC Log LCD Power Off Power
Cycle
Reset
TRUE FALSE TRUE TRUE TRUE TRUE FALSE FALSE FALSE
VDR51
Message The consistency check process made corrections and completed on
arg1
.
Arguments
arg1 =
virtual disk
Detailed
Description
The consistency check completed on the virtual disk after making corrections.
Recommended
Response Action
No response action is required.
Category Storage
SubCategory VDR = Virtual Disk
Severity Severity 3 (Informational)
Trap/EventID 4355
LCD Message No LCD message display defined.
Initial Default. SNMP Alert;#LCD;#Remote System Log
Filter
Visibility
IPMI Alert SNMP
Alert
Email
Alert
LC Log LCD Power Off Power
Cycle
Reset
TRUE FALSE TRUE TRUE TRUE TRUE FALSE FALSE FALSE
VDR52
Message The consistency check found inconsistent parity data on
arg1
.
Arguments
arg1 =
virtual disk
Detailed
Description
The data on physical disk members of the virtual disk does not match. Redundancy may be lost.
Recommended
Response Action
Rerun the consistency check task. If you receive this message again, verify the health of the
physical disks included in the virtual disk. See the storage hardware documentation for more
information. Review messages for significant messages related to the physical disks. If a
physical disk has a problem, replace it and restore from a backup copy. Contact technical
support if the issue persists.
Category Storage
SubCategory VDR = Virtual Disk
Severity Severity 2 (Warning)
884