Messages Reference Guide
SWC8611
Message Profile "
arg1
" and Server (Service Tag:
arg2
in Slot
arg3
are not compatible.
Arguments
•
arg1 =
profile_name
•
arg2 =
service tag
•
arg3 =
server_number
Detailed
Description
The selected profile version and the target server are not compatible. The CMC cannot perform
the cloning operation.
Recommended
Response Action
Select the correct version of profile and/or server and retry the operation
Category Audit
SubCategory SWC = Software Config
Severity Severity 2 (Warning)
Trap/EventID FALSE
LCD Message No LCD message display defined.
Initial Default. None
Filter
Visibility
IPMI Alert SNMP
Alert
Email
Alert
LC Log LCD Power Off Power
Cycle
Reset
FALSE FALSE FALSE FALSE FALSE FALSE FALSE FALSE FALSE
SWC8612
Message Failed to Fully Extract Boot Device from Stored Profile:
arg1
Arguments
•
arg1 =
key_properties
Detailed
Description
The selected profile is corrupt. Recreate a new profile with the desired properties, or use a
different profile.
Recommended
Response Action
Recreate or use a different profile.
Category Audit
SubCategory SWC = Software Config
Severity Severity 2 (Warning)
Trap/EventID FALSE
LCD Message No LCD message display defined.
Initial Default. None
781