Messages Reference Guide
Initial Default. SNMP Alert;#LCD;#Remote System Log
Filter
Visibility
IPMI Alert SNMP
Alert
Email
Alert
LC Log LCD Power Off Power
Cycle
Reset
TRUE FALSE TRUE TRUE TRUE TRUE FALSE FALSE FALSE
BAT1007
Message The battery on
arg1
learn cycle will start in
arg2
hours.
Arguments
•
arg1 =
Controller name
•
arg2 =
arg
Detailed
Description
This alert is provided for informational purposes.
Recommended
Response Action
No response action is required.
Category Storage
SubCategory BAT = Battery Event
Severity Severity 3 (Informational)
Trap/EventID 4275
LCD Message No LCD message display defined.
Initial Default. SNMP Alert;#LCD;#Remote System Log
Filter
Visibility
IPMI Alert SNMP
Alert
Email
Alert
LC Log LCD Power Off Power
Cycle
Reset
TRUE FALSE TRUE TRUE TRUE TRUE FALSE FALSE FALSE
BAT1008
Message Write policy on
arg1
was changed to Write Through.
Arguments
•
arg1 =
controller name
Detailed
Description
The controller battery cannot maintain cached data for the required period of time. For
example, if the required period of time is 24 hours, then the battery cannot maintain cached
data for 24 hours.
Recommended
Response Action
Verify the battery health is good. See the storage hardware documentation to verify battery
health. Contact technical support.
Category Storage
SubCategory BAT = Battery Event
Severity Severity 2 (Warning)
75