Messages Reference Guide
RDU8523
Message CMC
arg1
: reset by peer CMC
Arguments
•
arg1 =
slot number
Detailed
Description
The CMCidentified in the message was reset by other CMC. This occurs during failover and
CMC firmware update to the standby CMC.
Recommended
Response Action
No response action is required.
Category Audit
SubCategory RDU = Redundancy
Severity Severity 3 (Informational)
Trap/EventID FALSE
LCD Message No LCD message display defined.
Initial Default. LC Log
Filter
Visibility
IPMI Alert SNMP
Alert
Email
Alert
LC Log LCD Power Off Power
Cycle
Reset
FALSE FALSE FALSE FALSE TRUE FALSE FALSE FALSE FALSE
RDU8524
Message CMC
arg1
: failover is not allowed
Arguments
•
arg1 =
slot number
Detailed
Description
CMC failover action is not allowed in the current configuration.
Recommended
Response Action
No response action is required.
Category Audit
SubCategory RDU = Redundancy
Severity Severity 3 (Informational)
Trap/EventID FALSE
LCD Message No LCD message display defined.
Initial Default. LC Log
636