Messages Reference Guide

Trap/EventID FALSE
LCD Message No LCD message display defined.
Initial Default. LC Log
Filter
Visibility
IPMI Alert SNMP
Alert
Email
Alert
LC Log LCD Power Off Power
Cycle
Reset
FALSE FALSE FALSE FALSE TRUE FALSE FALSE FALSE FALSE
RDU8502
Message CMC
arg1
cannot go standby since the other CMC is not present or healthy.
Arguments
arg1 =
slot number
Detailed
Description
For failover to occur, the standby CMC needs to be present, at the same version as the primary
and healthy. During failover, the active CMC resets and the standby CMC becomes active. This
message is logged when the standby CMC is absent, unhealthy or at a different firmware
version.
Recommended
Response Action
Check the status of the standby CMC and make sure the firmware version matches the primary
CMC. Then reseat the CMC and retry the operation. If the issue persists, contact your service
provider.
Category Audit
SubCategory RDU = Redundancy
Severity Severity 3 (Informational)
Trap/EventID FALSE
LCD Message No LCD message display defined.
Initial Default. LC Log
Filter
Visibility
IPMI Alert SNMP
Alert
Email
Alert
LC Log LCD Power Off Power
Cycle
Reset
FALSE FALSE FALSE FALSE TRUE FALSE FALSE FALSE FALSE
RDU8506
Message CMC
arg1
: enable failover
Arguments
arg1 =
slot number
Detailed
Description
CMC failover is enabled.
Recommended
Response Action
No response action is required.
626