Messages Reference Guide
Filter
Visibility
IPMI Alert SNMP
Alert
Email
Alert
LC Log LCD Power Off Power
Cycle
Reset
FALSE FALSE FALSE FALSE TRUE FALSE FALSE FALSE FALSE
PWR8582
Message Chassis Management Controller is unable to turn on server-
arg1
because Max Power
Conservation Mode is enabled.
Arguments
•
arg1 =
slot number
Detailed
Description
Unable to turn on the server identified in the message because the Max Power Conservation
Mode (MPCM) is enabled. After MPCM is enabled, the chassis will be in power conservation
mode and the CMC cannot process any further server power on operation requests.
Recommended
Response Action
Disable the Max Power Conservation Mode and retry the operation.
Category Audit
SubCategory PWR = Power Usage
Severity Severity 3 (Informational)
Trap/EventID FALSE
LCD Message No LCD message display defined.
Initial Default. None
Filter
Visibility
IPMI Alert SNMP
Alert
Email
Alert
LC Log LCD Power Off Power
Cycle
Reset
FALSE FALSE FALSE FALSE FALSE FALSE FALSE FALSE FALSE
PWR8583
Message Chassis Management Controller is unable to turn on server-
arg1
because unacknowledged
110V PSUs are present.
Arguments
•
arg1 =
slot number
Detailed
Description
To enable 110V operation, the Allow 110VAC Operation feature must be enabled. If the feature
is not enabled, the server turn-on operation will not be processed.
Recommended
Response Action
On the Power Configuration page, in the Web UI, select the Allow 110VAC Operation for power
supplies and retry the operation. Using the RACADM utility, run the following command,
"racadm config -g cfgChassisPower -o cfgChassisAllow110VACOperation 1".
Category Audit
SubCategory PWR = Power Usage
Severity Severity 3 (Informational)