Messages Reference Guide
PWR8580
Message Chassis Management Controller is unable to turn on server-
arg1
because the Chassis is not
turned on.
Arguments
•
arg1 =
slot number
Detailed
Description
The power on request for the server identified in the message was not successful because the
Chassis is turned off.
Recommended
Response Action
Turn on the Chassis, and then retry the operation. To turn on the Chassis using the Chassis
Management Controller Web UI, go to Chassis Overview > Power > Control, select the Power
On System option, and then click Apply.
Category Audit
SubCategory PWR = Power Usage
Severity Severity 3 (Informational)
Trap/EventID FALSE
LCD Message No LCD message display defined.
Initial Default. LC Log;#None
Filter
Visibility
IPMI Alert SNMP
Alert
Email
Alert
LC Log LCD Power Off Power
Cycle
Reset
FALSE FALSE FALSE FALSE TRUE FALSE FALSE FALSE FALSE
PWR8581
Message Chassis Management Controller is unable to turn on server-
arg1
because another chassis
power operation is in progress.
Arguments
•
arg1 =
slot number
Detailed
Description
A chassis power operation is currently in progress and the server identified in the message
could not be turned on.
Recommended
Response Action
Wait until the current chassis power operation is complete and the chassis is On and then retry
the operation.
Category Audit
SubCategory PWR = Power Usage
Severity Severity 3 (Informational)
Trap/EventID FALSE
LCD Message No LCD message display defined.
Initial Default. LC Log;#None
587