Messages Reference Guide
Arguments
•
arg1 =
slot number
Detailed
Description
The Chassis Management Controller is unable to turn on the iDRAC because power required is
less than available power.
Recommended
Response Action
Make sure there is enough power supply to distribute power. Go to, the Chassis Overview >
Power > Power Budget Status. In the Total Input Power Available For Allocation field, view the
available power. To add more power, insert more PSUs or remove unused components from
the chassis. Remove and reinsert the server when enough power is available.
Category Audit
SubCategory PWR = Power Usage
Severity Severity 2 (Warning)
Trap/EventID 8418
LCD Message No LCD message display defined.
Initial Default. SNMP Alert;#EMAIL Alert;#LC Log;#Remote System Log
Filter
Visibility
IPMI Alert SNMP
Alert
Email
Alert
LC Log LCD Power Off Power
Cycle
Reset
TRUE FALSE TRUE TRUE TRUE FALSE FALSE FALSE FALSE
PWR8579
Message Request to reset the CMC
arg1
is initiated.
Arguments
•
arg1 =
slot id
Detailed
Description
A request to reset the CMC identified in the message is inititated. If a second CMC is present, a
failover to the other CMC will occur as a result.
Recommended
Response Action
No response action is required.
Category Audit
SubCategory PWR = Power Usage
Severity Severity 3 (Informational)
Trap/EventID FALSE
LCD Message No LCD message display defined.
Initial Default. LC Log
Filter
Visibility
IPMI Alert SNMP
Alert
Email
Alert
LC Log LCD Power Off Power
Cycle
Reset
FALSE FALSE FALSE FALSE TRUE FALSE FALSE FALSE FALSE
586