Messages Reference Guide

Recommended
Response Action
Wait for three minutes, and then retry the operation. If the issue persists, remove and reinsert
the server and wait for the iDRAC to finish restarting before retying the operation.
Category Audit
SubCategory PWR = Power Usage
Severity Severity 1 (Critical)
Trap/EventID 8417
LCD Message No LCD message display defined.
Initial Default. SNMP Alert;#EMAIL Alert;#LC Log;#Remote System Log
Filter
Visibility
IPMI Alert SNMP
Alert
Email
Alert
LC Log LCD Power Off Power
Cycle
Reset
TRUE FALSE TRUE TRUE TRUE FALSE FALSE FALSE FALSE
PWR8575
Message Initated the Virtual Reseat of server
arg1
.
Arguments
arg1 =
server id
Detailed
Description
A Virtual Reseat for the server identified in the message is initiated. A Virtual Reseat is the
same as removing and inserting a server.
Recommended
Response Action
No response action is required.
Category Audit
SubCategory PWR = Power Usage
Severity Severity 3 (Informational)
Trap/EventID FALSE
LCD Message No LCD message display defined.
Initial Default. LC Log
Filter
Visibility
IPMI Alert SNMP
Alert
Email
Alert
LC Log LCD Power Off Power
Cycle
Reset
FALSE FALSE FALSE FALSE TRUE FALSE FALSE FALSE FALSE
PWR8576
Message Unable to turn on the Sleeve
arg1
after Virtual Reseat.
Arguments
arg1 =
sleeve number
584