Messages Reference Guide

SubCategory PWR = Power Usage
Severity Severity 3 (Informational)
Trap/EventID FALSE
LCD Message No LCD message display defined.
Initial Default. LC Log
Filter
Visibility
IPMI Alert SNMP
Alert
Email
Alert
LC Log LCD Power Off Power
Cycle
Reset
FALSE FALSE FALSE FALSE TRUE FALSE FALSE FALSE FALSE
PWR8573
Message The Chassis Management Controller is unable to communicate to the iDRAC, when trying to
turn off the server
arg1
.
Arguments
arg1 =
server id
Detailed
Description
The Chassis Management Controller is not able to communicate with the iDRAC on the server
identified in the message. Therefore the server could not be turned off. This situation may
occur when iDRAC is restarting.
Recommended
Response Action
Wait for three minutes, and then retry the operation. If the issue persists, remove and reinsert
the server and wait for the iDRAC to finish restarting before retying the operation.
Category Audit
SubCategory PWR = Power Usage
Severity Severity 2 (Warning)
Trap/EventID 8418
LCD Message No LCD message display defined.
Initial Default. SNMP Alert;#EMAIL Alert;#LC Log;#Remote System Log
Filter
Visibility
IPMI Alert SNMP
Alert
Email
Alert
LC Log LCD Power Off Power
Cycle
Reset
TRUE FALSE TRUE TRUE TRUE FALSE FALSE FALSE FALSE
PWR8574
Message The Chassis Management Controller is unable to communicate to the iDRAC, when trying to
hard reset the server
arg1
.
Arguments
arg1 =
slot number
Detailed
Description
The Chassis Management Controller is not able to communicate with the iDRAC on the server
identified in the message. Therefore the server could not be hard reset. This situation may
occur when iDRAC is restarting.
583