Messages Reference Guide

Initial Default. LC Log
Filter
Visibility
IPMI Alert SNMP
Alert
Email
Alert
LC Log LCD Power Off Power
Cycle
Reset
FALSE FALSE FALSE FALSE TRUE FALSE FALSE FALSE FALSE
PWR8560
Message Unable to turn on I/O Module
arg1
due to insufficient chassis power.
Arguments
arg1 =
IOM slot name
Detailed
Description
Unable to turn on the I/O Module identified in the message due to insufficient chassis power.
Recommended
Response Action
Utilize the Chassis Management Controller (CMC) web interface to check available power and
I/O Module power requirements. If sufficient power is available, restart the CMC and retry the
operation. If sufficient power is not availble due to an insufficient number of PSUs, add
additional PSU(s) and reinsert the I/O Module.
Category Audit
SubCategory PWR = Power Usage
Severity Severity 1 (Critical)
Trap/EventID 8417
LCD Message No LCD message display defined.
Initial Default. SNMP Alert;#EMAIL Alert;#LC Log;#Remote System Log
Filter
Visibility
IPMI Alert SNMP
Alert
Email
Alert
LC Log LCD Power Off Power
Cycle
Reset
TRUE FALSE TRUE TRUE TRUE FALSE FALSE FALSE FALSE
PWR8561
Message Unable to power on server
arg1
because of iDRAC communication issue.
Arguments
arg1 =
server number
Detailed
Description
The Chassis Management Controller is unable to communicate with the Server iDRAC service
processor and the server could not be powered on. This situation may occur when iDRAC is
rebooting.
Recommended
Response Action
Wait for three minutes and then retry the operation. If the issue persists, remove and reinsert
the server and wait for the iDRAC to finish restarting.
Category Audit
SubCategory PWR = Power Usage
576