Messages Reference Guide
SubCategory PWR = Power Usage
Severity Severity 3 (Informational)
Trap/EventID FALSE
LCD Message No LCD message display defined.
Initial Default. LC Log
Filter
Visibility
IPMI Alert SNMP
Alert
Email
Alert
LC Log LCD Power Off Power
Cycle
Reset
FALSE FALSE FALSE FALSE TRUE FALSE FALSE FALSE FALSE
PWR8552
Message Chassis Management Controller is unable to turn on
arg1
-
arg2
because of insufficient power.
Arguments
•
arg1 =
component name
•
arg2 =
component id
Detailed
Description
There is insufficient power for the component identified in the message to turn on.
Recommended
Response Action
Make sure there is enough power supply to distribute power. Using the CMC Web UI, go to
Chassis Overview > Power > Power Budget Status. In the Total Input Power Available For
Allocation field view the available power. To add more power, insert more PSUs or remove
unused components from the chassis. Contact your service provider for information on the
power required for the component identified in the message.
Category Audit
SubCategory PWR = Power Usage
Severity Severity 2 (Warning)
Trap/EventID 8418
LCD Message No LCD message display defined.
Initial Default. SNMP Alert;#EMAIL Alert;#LC Log;#Remote System Log
Filter
Visibility
IPMI Alert SNMP
Alert
Email
Alert
LC Log LCD Power Off Power
Cycle
Reset
TRUE FALSE TRUE TRUE TRUE FALSE FALSE FALSE FALSE
PWR8554
Message Chassis Management Controller is unable to send power allocation information to
arg1
-
arg2
at
priority
arg3
.
Arguments
•
arg1 =
component name
•
arg2 =
component id
573