Messages Reference Guide

Recommended
Response Action
No response action is required. Make sure there are enough PSUs to support redundancy at
the specified power budget.
Category Audit
SubCategory PWR = Power Usage
Severity Severity 2 (Warning)
Trap/EventID FALSE
LCD Message No LCD message display defined.
Initial Default. LC Log
Filter
Visibility
IPMI Alert SNMP
Alert
Email
Alert
LC Log LCD Power Off Power
Cycle
Reset
FALSE FALSE FALSE FALSE TRUE FALSE FALSE FALSE FALSE
PWR8509
Message Unable to change the server power priority because Server Based Power Management mode
is enabled.
Detailed
Description
Unable to change the server power priority because Server Based Power Management mode
is enabled.
Recommended
Response Action
The server power priority can be changed once Server Based Power Management mode is
disabled. Using the CMC Web UI, navigate to the Chassis Overview > Power > Configuration
page, then uncheck the Enable Server Based Power Management checkbox. Retry the
operation.
Category Audit
SubCategory PWR = Power Usage
Severity Severity 2 (Warning)
Trap/EventID FALSE
LCD Message No LCD message display defined.
Initial Default. LC Log
Filter
Visibility
IPMI Alert SNMP
Alert
Email
Alert
LC Log LCD Power Off Power
Cycle
Reset
FALSE FALSE FALSE FALSE TRUE FALSE FALSE FALSE FALSE
PWR8510
Message Unable to set chassis power property
arg1
.
Arguments
arg1 =
property name
553