Messages Reference Guide
Initial Default. LC Log
Filter
Visibility
IPMI Alert SNMP
Alert
Email
Alert
LC Log LCD Power Off Power
Cycle
Reset
TRUE FALSE TRUE TRUE TRUE FALSE FALSE FALSE FALSE
PSU0039
Message An under current fault detected on power supply
arg1
.
Arguments
•
arg1 =
number
Detailed
Description
Insufficient amount of current to keep power supply operating at a normal levels.
Recommended
Response Action
1) Remove and re-install the power supply input cord. 2) Check power distribution or PSU input
source for anomalies. 3) If the issue persists, contact technical support. Refer to the product
documentation to choose a convenient contact method.
Category System Health
SubCategory PSU = Power Supply
Severity Severity 1 (Critical)
Trap/EventID 2185
LCD Message Under current fault detected on PSU <number>. Check PSU.
Initial Default. LC Log
Filter
Visibility
IPMI Alert SNMP
Alert
Email
Alert
LC Log LCD Power Off Power
Cycle
Reset
TRUE FALSE TRUE TRUE TRUE FALSE FALSE FALSE FALSE
PSU0040
Message An output under voltage fault detected on power supply
arg1
.
Arguments
•
arg1 =
number
Detailed
Description
The power supply output voltage is insufficient to keep system operating at a normal levels.
Recommended
Response Action
1) Remove the power supply input cord and then remove power supply. 2) Re-install the power
supply and then re-install the power supply cord. 3) If the issue persists, contact technical
support. Refer to the product documentation to choose a convenient contact method.
Category System Health
SubCategory PSU = Power Supply
Severity Severity 1 (Critical)
542