Messages Reference Guide

Detailed
Description
None
Recommended
Response Action
No response action is required.
Category System Health
SubCategory PSU = Power Supply
Severity Severity 3 (Informational)
Trap/EventID 2187
LCD Message No LCD message display defined.
Initial Default. LC Log
Filter
Visibility
IPMI Alert SNMP
Alert
Email
Alert
LC Log LCD Power Off Power
Cycle
Reset
TRUE FALSE TRUE TRUE TRUE FALSE FALSE FALSE FALSE
PSU0002
Message A predictive failure detected on power supply
arg1
.
Arguments
arg1 =
number
Detailed
Description
System performance and power redundancy may be degraded or lost.
Recommended
Response Action
Remove and re-install the power supply at the next service window. If the issue persists,
contact technical support. Refer to the product documentation to choose a convenient contact
method.
Category System Health
SubCategory PSU = Power Supply
Severity Severity 2 (Warning)
Trap/EventID 2186
LCD Message Predictive failure on PSU <number>. Check PSU
Initial Default. LC Log
Filter
Visibility
IPMI Alert SNMP
Alert
Email
Alert
LC Log LCD Power Off Power
Cycle
Reset
TRUE FALSE TRUE TRUE TRUE FALSE FALSE FALSE FALSE
PSU0003
Message The power input for power supply
arg1
is lost.
523