Messages Reference Guide

Detailed
Description
The power supply is not providing any power. This may be because the power supply switch is
in the off position or the power supply has failed.
Recommended
Response Action
Check whether the power switch on the power supply unit is turned off or on. If it is turned off,
turn it on. If the problem is not corrected, verify that the power cord is attached and functional.
See the storage hardware documentation for more information.
Category Storage
SubCategory PSU = Power Supply
Severity Severity 2 (Warning)
Trap/EventID 4234
LCD Message No LCD message display defined.
Initial Default. SNMP Alert;#LCD;#Remote System Log
Filter
Visibility
IPMI Alert SNMP
Alert
Email
Alert
LC Log LCD Power Off Power
Cycle
Reset
TRUE FALSE TRUE TRUE TRUE TRUE FALSE FALSE FALSE
PSU1010
Message The DC power supply is switched off.
Detailed
Description
The power supply unit is switched off. Either you have switched off the power supply unit or it
is defective.
Recommended
Response Action
Check to see whether the power switch is turned off or on. If it is turned off, turn it on. If the
problem is not corrected, verify that the power cord is attached and functional. If the problem
continues or if the power switch is already turned on, then replace the power supply unit.
Category Storage
SubCategory PSU = Power Supply
Severity Severity 1 (Critical)
Trap/EventID 4233
LCD Message No LCD message display defined.
Initial Default. SNMP Alert;#LCD;#Remote System Log
Filter
Visibility
IPMI Alert SNMP
Alert
Email
Alert
LC Log LCD Power Off Power
Cycle
Reset
TRUE FALSE TRUE TRUE TRUE TRUE FALSE FALSE FALSE
PSU1002
Message
arg1
was removed
Arguments
arg1 =
PSU Sensor Name
519