PSU8503
Message The PSU in slot
arg1
detected 220 VAC input voltage and does not match chassis configuration.
Arguments
arg1 =
slot number
Detailed
Description
The input voltage of the PSU specified in the message does not match the input voltage of the
PSUs already present in the chassis.
Recommended
Response Action
Do the following: 1) Check if the input voltage of all the PSUs are the same. 2) If the input
voltage of the PSU specified in the message is not the same, then remove the unmatched PSU.
Category Audit
SubCategory PSU = Power Supply
Severity Severity 2 (Warning)
Trap/EventID FALSE
LCD Message No LCD message display defined.
Initial Default. LC Log
Filter
Visibility
IPMI Alert SNMP
Alert
Email
Alert
LC Log LCD Power Off Power
Cycle
Reset
FALSE FALSE FALSE FALSE TRUE FALSE FALSE FALSE FALSE
PSU8504
Message The Allow 110 VAC Operation overload risk is not acknowledged.
Detailed
Description
Selecting the Allow 110 VAC Operation involves potential risk that an overload can occur. The
overload risk was not acknowledged in the CMC Web interface when the selection was made.
Recommended
Response Action
Select the Allow 110 VAC Operation and accept the subsequent dialog that acknowledges the
overload risk.
Category Audit
SubCategory PSU = Power Supply
Severity Severity 3 (Informational)