Messages Reference Guide

Recommended
Response Action
Compare system memory installation to supported system memory configurations. Reduce
system configuration to minimum memory configuration.
Category System Health
SubCategory PST = BIOS POST
Severity Severity 1 (Critical)
Trap/EventID FALSE
LCD Message Memory initialization error. Contact support
Initial Default. FALSE
Filter
Visibility
IPMI Alert SNMP
Alert
Email
Alert
LC Log LCD Power Off Power
Cycle
Reset
FALSE FALSE FALSE FALSE FALSE FALSE FALSE FALSE FALSE
PST0143
Message Intel Trusted Execution Technology (TXT) fatal error.
Detailed
Description
TXT boot failed. This could be related to memory errors or an error with the system TXT
configuration. A socketed TPM module may have been removed. This exception occurred early
in system power on, thus the system may not display video.
Recommended
Response Action
Check TPM presence. Remove and reapply input power. If the problem persists, contact
technical support. Refer to the product documentation to choose a convenient contact method.
Category System Health
SubCategory PST = BIOS POST
Severity Severity 1 (Critical)
Trap/EventID FALSE
LCD Message Intel Trusted Execution Technology (TXT) fatal error. Contact support
Initial Default. FALSE
Filter
Visibility
IPMI Alert SNMP
Alert
Email
Alert
LC Log LCD Power Off Power
Cycle
Reset
FALSE FALSE FALSE FALSE FALSE FALSE FALSE FALSE FALSE
PST0192
Message Shut-down test failed.
Detailed
Description
System BIOS shutdown test failed during POST. This exception occurred early in system power
on, thus the system may not display video. (BIOS POST exception code C0).
Recommended
Response Action
Check system event log for CMOS battery exceptions. Remove and reapply input power. If the
problem persists, contact technical support. Refer to the product documentation to choose a
convenient contact method.