Messages Reference Guide

PST0138
Message SuperIO failed.
Detailed
Description
System BIOS detected a failure with the SIO. This exception occurred early in system power
on, thus the system may not display video. (BIOS POST code exception code 8A)
Recommended
Response Action
Remove and reapply input power. If the problem persists, contact technical support. Refer to
the product documentation to choose a convenient contact method.
Category System Health
SubCategory PST = BIOS POST
Severity Severity 1 (Critical)
Trap/EventID FALSE
LCD Message SuperIO failure. Power cycle system
Initial Default. FALSE
Filter
Visibility
IPMI Alert SNMP
Alert
Email
Alert
LC Log LCD Power Off Power
Cycle
Reset
FALSE FALSE FALSE FALSE FALSE FALSE FALSE FALSE FALSE
PST0139
Message Keyboard controller failed.
Detailed
Description
System BIOS detected a failure with the Keyboard Controller. This exception occurred early in
system power on, thus the system may not display video. (BIOS POST exception code 8B)
Recommended
Response Action
Remove and reapply input power. If the problem persists, contact technical support. Refer to
the product documentation to choose a convenient contact method.
Category System Health
SubCategory PST = BIOS POST
Severity Severity 1 (Critical)
Trap/EventID FALSE
LCD Message Keyboard controller failed. Power cycle system
Initial Default. FALSE
Filter
Visibility
IPMI Alert SNMP
Alert
Email
Alert
LC Log LCD Power Off Power
Cycle
Reset
FALSE FALSE FALSE FALSE FALSE FALSE FALSE FALSE FALSE
PST0140
Message System management interrupt initialization failed.
502