Messages Reference Guide

Detailed
Description
The controller detected a drive removal
Recommended
Response Action
If unintended, verify drive installation. Remove and reseat the indicated disk. If the problem
persists, contact technical support. Refer to the product documentation to choose a
convenient contact method.
Category System Health
SubCategory PDR = Physical Disk
Severity Severity 1 (Critical)
Trap/EventID FALSE
LCD Message Drive <number> is removed. Check drive
Initial Default. FALSE
Filter
Visibility
IPMI Alert SNMP
Alert
Email
Alert
LC Log LCD Power Off Power
Cycle
Reset
FALSE FALSE FALSE FALSE FALSE FALSE FALSE FALSE FALSE
PDR1101
Message Fault detected on drive
arg1
.
Arguments
arg1 =
number
Detailed
Description
The controller detected a failure on the disk and has taken the disk offline.
Recommended
Response Action
Remove and reseat the failed disk. If the problem persists, contact technical support. Refer to
the product documentation to choose a convenient contact method.
Category System Health
SubCategory PDR = Physical Disk
Severity Severity 1 (Critical)
Trap/EventID FALSE
LCD Message Fault detected on drive <number>. Check drive.
Initial Default. FALSE
Filter
Visibility
IPMI Alert SNMP
Alert
Email
Alert
LC Log LCD Power Off Power
Cycle
Reset
FALSE FALSE FALSE FALSE FALSE FALSE FALSE FALSE FALSE
PDR1102
Message A predictive failure detected on drive
arg1
.
478