Messages Reference Guide
Category Storage
SubCategory PDR = Physical Disk
Severity Severity 3 (Informational)
Trap/EventID 4347
LCD Message No LCD message display defined.
Initial Default. SNMP Alert;#LCD;#Remote System Log
Filter
Visibility
IPMI Alert SNMP
Alert
Email
Alert
LC Log LCD Power Off Power
Cycle
Reset
TRUE FALSE TRUE TRUE TRUE TRUE FALSE FALSE FALSE
PDR98
Message Command timeout occurred on
arg1
.
arg2
.
Arguments
•
arg1 =
physical disk
•
arg2 =
args
Detailed
Description
An error occurred while performing an action on the disk.
Recommended
Response Action
Check the disk is present or replace the disk.
Category Storage
SubCategory PDR = Physical Disk
Severity Severity 2 (Warning)
Trap/EventID 4346
LCD Message No LCD message display defined.
Initial Default. SNMP Alert;#LCD;#Remote System Log
Filter
Visibility
IPMI Alert SNMP
Alert
Email
Alert
LC Log LCD Power Off Power
Cycle
Reset
TRUE FALSE TRUE TRUE TRUE TRUE FALSE FALSE FALSE
PDR100
Message Dedicated Hot Spare
arg1
no longer useful for all arrays.
Arguments
•
arg1 =
PD Name
Detailed
Description
The controller is not able to communicate with a disk that is assigned as a dedicated hot spare.
The disk may have been removed. There may also be a bad or loose cable.
475