Messages Reference Guide
Severity Severity 2 (Warning)
Trap/EventID 4346
LCD Message No LCD message display defined.
Initial Default. SNMP Alert;#LCD;#Remote System Log
Filter
Visibility
IPMI Alert SNMP
Alert
Email
Alert
LC Log LCD Power Off Power
Cycle
Reset
TRUE FALSE TRUE TRUE TRUE TRUE FALSE FALSE FALSE
PDR68
Message Dedicated spare
arg1
imported as global due to missing disk groups.
Arguments
•
arg1 =
PD Name
Detailed
Description
This alert is provided for informational purposes
Recommended
Response Action
No response action is required.
Category Storage
SubCategory PDR = Physical Disk
Severity Severity 3 (Informational)
Trap/EventID 4347
LCD Message No LCD message display defined.
Initial Default. SNMP Alert;#LCD;#Remote System Log
Filter
Visibility
IPMI Alert SNMP
Alert
Email
Alert
LC Log LCD Power Off Power
Cycle
Reset
TRUE FALSE TRUE TRUE TRUE TRUE FALSE FALSE FALSE
PDR69
Message Rebuild not possible on
arg1
.
Arguments
•
arg1 =
physical disk
Detailed
Description
Physical disk inserted is of the incorrect protocol. SAS or SATA mixing is not supported in the
same virtual disk.
Recommended
Response Action
Remove drive, insert correct protocol type, and force a rebuild as imposed for controller and
system.
Category Storage
462