Messages Reference Guide
Recommended
Response Action
No response action is required.
Category Storage
SubCategory PDR = Physical Disk
Severity Severity 3 (Informational)
Trap/EventID 4347
LCD Message No LCD message display defined.
Initial Default. SNMP Alert;#LCD;#Remote System Log
Filter
Visibility
IPMI Alert SNMP
Alert
Email
Alert
LC Log LCD Power Off Power
Cycle
Reset
TRUE FALSE TRUE TRUE TRUE TRUE FALSE FALSE FALSE
PDR35
Message The only hot spare available is a SATA disk
arg1
.
Arguments
•
arg1 =
PD Name
Detailed
Description
The only physical disk available to be assigned as a hot spare is using SATA technology. The
physical disks in the virtual disk are using SAS technology. Because of this difference in
technology, the hot spare cannot rebuild data if one of the physical disks in the virtual disk
fails.
Recommended
Response Action
Add a SAS disk that is large enough to be used as the hot spare and assign the new disk as a
hot spare.
Category Storage
SubCategory PDR = Physical Disk
Severity Severity 2 (Warning)
Trap/EventID 4346
LCD Message No LCD message display defined.
Initial Default. SNMP Alert;#LCD;#Remote System Log
Filter
Visibility
IPMI Alert SNMP
Alert
Email
Alert
LC Log LCD Power Off Power
Cycle
Reset
TRUE FALSE TRUE TRUE TRUE TRUE FALSE FALSE FALSE
PDR36
Message The only hot spare available is a SAS disk
arg1
.
Arguments
•
arg1 =
PD Name
445