Messages Reference Guide
Filter
Visibility
IPMI Alert SNMP
Alert
Email
Alert
LC Log LCD Power Off Power
Cycle
Reset
TRUE FALSE TRUE TRUE TRUE TRUE FALSE FALSE FALSE
PDR20
Message SMART configuration change for
arg1
.
Arguments
•
arg1 =
PD Name
Detailed
Description
A disk has received a SMART alert (predictive failure) after a configuration change. The disk is
likely to fail in the near future.
Recommended
Response Action
Replace the disk that has received the SMART alert. If the physical disk is a member of a non-
redundant virtual disk, then back up the data before replacing the disk. Removing a physical
disk that is included in a non-redundant virtual disk will cause the virtual disk to fail and may
cause data loss.
Category Storage
SubCategory PDR = Physical Disk
Severity Severity 1 (Critical)
Trap/EventID 4345
LCD Message No LCD message display defined.
Initial Default. SNMP Alert;#LCD;#Remote System Log
Filter
Visibility
IPMI Alert SNMP
Alert
Email
Alert
LC Log LCD Power Off Power
Cycle
Reset
TRUE FALSE TRUE TRUE TRUE TRUE FALSE FALSE FALSE
PDR21
Message SMART warning for
arg1
Arguments
•
arg1 =
PD Name
Detailed
Description
A disk has received a SMART alert (predictive failure). The disk is likely to fail in the near
future.
Recommended
Response Action
Replace the disk that has received the SMART alert. If the physical disk is a member of a non-
redundant virtual disk, then back up the data before replacing the disk. Removing a physical
disk that is included in a non-redundant virtual disk will cause the virtual disk to fail and may
cause data loss.
Category Storage
SubCategory PDR = Physical Disk
Severity Severity 2 (Warning)
437