Messages Reference Guide
SubCategory PDR = Physical Disk
Severity Severity 3 (Informational)
Trap/EventID 4347
LCD Message No LCD message display defined.
Initial Default. SNMP Alert;#LCD;#Remote System Log
Filter
Visibility
IPMI Alert SNMP
Alert
Email
Alert
LC Log LCD Power Off Power
Cycle
Reset
TRUE FALSE TRUE TRUE TRUE TRUE FALSE FALSE FALSE
PDR5
Message
arg1
is removed.
Arguments
•
arg1 =
PD Name
Detailed
Description
A physical disk has been removed from the disk group. This alert can also be caused by loose
or defective cables or by problems with the enclosure.
Recommended
Response Action
Do one of the following: 1) If a physical disk was removed from the disk group, either replace
the disk or restore the original disk. Identify the disk that was removed by locating the disk that
has a red "X" for its status. 2) Perform a rescan after replacing or restoring the disk. 3) If a disk
was not removed from the disk group, then check for cable problems. Refer to product
documentation for more information on checking the cables. 4) Make sure that the enclosure is
powered on. 5) If the problem persists, check the enclosure documentation for further
diagnostic information.
Category Storage
SubCategory PDR = Physical Disk
Severity Severity 2 (Warning)
Trap/EventID 4346
LCD Message No LCD message display defined.
Initial Default. SNMP Alert;#LCD;#Remote System Log
Filter
Visibility
IPMI Alert SNMP
Alert
Email
Alert
LC Log LCD Power Off Power
Cycle
Reset
TRUE FALSE TRUE TRUE TRUE TRUE FALSE FALSE FALSE
PDR6
Message
arg1
is offline.
Arguments
•
arg1 =
physical disk
429