Messages Reference Guide

SubCategory PCI = PCI Device
Severity Severity 2 (Warning)
Trap/EventID FALSE
LCD Message No LCD message display defined.
Initial Default. FALSE
Filter
Visibility
IPMI Alert SNMP
Alert
Email
Alert
LC Log LCD Power Off Power
Cycle
Reset
FALSE FALSE FALSE FALSE FALSE FALSE FALSE FALSE FALSE
PCI1362
Message Bus performance degraded for a component at slot
arg1
.
Arguments
arg1 =
number
Detailed
Description
System performance may be degraded. The bus is not operating at maximum speed or width.
Recommended
Response Action
Cycle input power, update component drivers, remove and re-install the device at the next
scheduled service time.
Category System Health
SubCategory PCI = PCI Device
Severity Severity 2 (Warning)
Trap/EventID FALSE
LCD Message No LCD message display defined.
Initial Default. FALSE
Filter
Visibility
IPMI Alert SNMP
Alert
Email
Alert
LC Log LCD Power Off Power
Cycle
Reset
FALSE FALSE FALSE FALSE FALSE FALSE FALSE FALSE FALSE
PCI2000
Message A fatal IO error detected on a component at bus
arg1
device
arg2
function
arg3
.
Arguments
arg1 =
bus
arg2 =
device
arg3 =
func
Detailed
Description
System performance may be degraded, or system may fail to operate.
414