Messages Reference Guide

LCD Message No LCD message display defined.
Initial Default. LC Log
Filter
Visibility
IPMI Alert SNMP
Alert
Email
Alert
LC Log LCD Power Off Power
Cycle
Reset
TRUE FALSE TRUE TRUE TRUE FALSE FALSE FALSE FALSE
HWC5037
Message I/O module
arg1
failed to boot.
Arguments
arg1 =
number
Detailed
Description
The firmware on the I/O module did not boot. The problem may be because the I/O module is
not inserted correctly.
Recommended
Response Action
Reseat I/O module. If problem persists, contact the service provider.
Category System Health
SubCategory HWC = Hardware Config
Severity Severity 1 (Critical)
Trap/EventID 2329
LCD Message No LCD message display defined.
Initial Default. LC Log
Filter
Visibility
IPMI Alert SNMP
Alert
Email
Alert
LC Log LCD Power Off Power
Cycle
Reset
TRUE FALSE TRUE TRUE TRUE FALSE FALSE FALSE FALSE
HWC1201
Message The
arg1
was removed from slot
arg2
.
Arguments
arg1 =
name
arg2 =
number
Detailed
Description
None
Recommended
Response Action
No response action is required.
Category System Health
SubCategory HWC = Hardware Config
289