Messages Reference Guide

Filter
Visibility
IPMI Alert SNMP
Alert
Email
Alert
LC Log LCD Power Off Power
Cycle
Reset
TRUE FALSE TRUE TRUE TRUE FALSE FALSE FALSE FALSE
HWC2006
Message The
arg1
is not installed correctly.
Arguments
arg1 =
name
Detailed
Description
The device may be necessary for proper operation. System functionality may be degraded.
Recommended
Response Action
Check presence, then re-install or reconnect.
Category System Health
SubCategory HWC = Hardware Config
Severity Severity 1 (Critical)
Trap/EventID FALSE
LCD Message <name> is not installed correctly. Check connection
Initial Default. FALSE
Filter
Visibility
IPMI Alert SNMP
Alert
Email
Alert
LC Log LCD Power Off Power
Cycle
Reset
FALSE FALSE FALSE FALSE FALSE FALSE FALSE FALSE FALSE
HWC2007
Message The
arg1
is installed correctly.
Arguments
arg1 =
name
Detailed
Description
None
Recommended
Response Action
No response action is required.
Category System Health
SubCategory HWC = Hardware Config
Severity Severity 3 (Informational)
Trap/EventID FALSE
LCD Message No LCD message display defined.
258