Messages Reference Guide

Category Storage
SubCategory CTL = Storage Contr
Severity Severity 3 (Informational)
Trap/EventID 4331
LCD Message No LCD message display defined.
Initial Default. SNMP Alert;#LCD;#Remote System Log
Filter
Visibility
IPMI Alert SNMP
Alert
Email
Alert
LC Log LCD Power Off Power
Cycle
Reset
TRUE FALSE TRUE TRUE TRUE TRUE FALSE FALSE FALSE
CTL76
Message A configuration command could not be committed to disk on
arg1
Arguments
arg1 =
Controller name
Detailed
Description
The controller encountered errors while applying the configuration on the physical disks. The
configuration command applied has not taken effect.
Recommended
Response Action
Re-issue the failed configuration command or try with a different set of physical disks. Contact
technical support if the problem persists.
Category Storage
SubCategory CTL = Storage Contr
Severity Severity 1 (Critical)
Trap/EventID 4329
LCD Message No LCD message display defined.
Initial Default. SNMP Alert;#LCD;#Remote System Log
Filter
Visibility
IPMI Alert SNMP
Alert
Email
Alert
LC Log LCD Power Off Power
Cycle
Reset
TRUE FALSE TRUE TRUE TRUE TRUE FALSE FALSE FALSE
CTL79
Message Controller in
arg1
is not supported and will not be powered on.
Arguments
arg1 =
controller slot
Detailed
Description
This controller does not support features required for this chassis. This controller will not be
powered on to prevent data loss.
201