Messages Reference Guide

Filter
Visibility
IPMI Alert SNMP
Alert
Email
Alert
LC Log LCD Power Off Power
Cycle
Reset
TRUE FALSE TRUE TRUE TRUE TRUE FALSE FALSE FALSE
CTL57
Message The factory default settings were restored on
arg1
.
Arguments
arg1 =
controller Name
Detailed
Description
The controller was reset to factory default configuration settings.
Recommended
Response Action
No response action is required.
Category Storage
SubCategory CTL = Storage Contr
Severity Severity 3 (Informational)
Trap/EventID 4331
LCD Message No LCD message display defined.
Initial Default. SNMP Alert;#LCD;#Remote System Log
Filter
Visibility
IPMI Alert SNMP
Alert
Email
Alert
LC Log LCD Power Off Power
Cycle
Reset
TRUE FALSE TRUE TRUE TRUE TRUE FALSE FALSE FALSE
CTL58
Message
arg1
SAS SMP communications error
arg2
Arguments
arg1 =
Controller name
arg2 =
args
Detailed
Description
The text for this alert is generated by the firmware and can vary depending on the situation.
The reference to SMP in this text refers to SAS Management Protocol.
Recommended
Response Action
There may be a SAS topology error. See the hardware documentation for information on
correct SAS topology configurations. There may be problems with the cables such as a loose
connection or an invalid cabling configuration. See the Cables Attached Correctly section for
more information on checking the cables. See the hardware documentation for information on
correct cabling configurations. Verify that the firmware version is supported.
Category Storage
SubCategory CTL = Storage Contr
Severity Severity 1 (Critical)
190