Messages Reference Guide

Trap/EventID FALSE
LCD Message No LCD message display defined.
Initial Default. FALSE
Filter
Visibility
IPMI Alert SNMP
Alert
Email
Alert
LC Log LCD Power Off Power
Cycle
Reset
FALSE FALSE FALSE FALSE FALSE FALSE FALSE FALSE FALSE
CPU0001
Message CPU
arg1
has a thermal trip (over-temperature) event.
Arguments
arg1 =
number
Detailed
Description
The processor temperature increased beyond the operational range. Thermal protection shut
down the processor. Factors external to the processor may have induced this exception.
Recommended
Response Action
Review logs for fan failures, replace failed fans. If no fan failures are detected, check inlet
temperature (if available) and reinstall processor heatsink.
Category System Health
SubCategory CPU = Processor
Severity Severity 1 (Critical)
Trap/EventID FALSE
LCD Message CPU <number> has a thermal trip. Check CPU heat sink
Initial Default. FALSE
Filter
Visibility
IPMI Alert SNMP
Alert
Email
Alert
LC Log LCD Power Off Power
Cycle
Reset
FALSE FALSE FALSE FALSE FALSE FALSE FALSE FALSE FALSE
CPU0002
Message CPU
arg1
has failed the built-in self-test (BIST).
Arguments
arg1 =
number
Detailed
Description
None
Recommended
Response Action
1) Turn system off and remove input power for one minute. Re-apply input power and turn
system on. 2) Make sure the processor is seated correctly. 3) If the issue still persists, contact
technical support. Refer to the product documentation to choose a convenient contact method.
Category System Health