Messages Reference Guide

Filter
Visibility
IPMI Alert SNMP
Alert
Email
Alert
LC Log LCD Power Off Power
Cycle
Reset
TRUE FALSE TRUE TRUE TRUE FALSE FALSE FALSE FALSE
CMC8538
Message Firmware version string is too long.
Detailed
Description
The length of the CMC firmware version to be sent in the message from local CMC to peer CMC
is too long. Under these conditions, CMC version in the message is displayed as 1.0.
Recommended
Response Action
No response action is required.
Category Audit
SubCategory CMC = Chassis Management Controller
Severity Severity 3 (Informational)
Trap/EventID FALSE
LCD Message No LCD message display defined.
Initial Default. LC Log
Filter
Visibility
IPMI Alert SNMP
Alert
Email
Alert
LC Log LCD Power Off Power
Cycle
Reset
FALSE FALSE FALSE FALSE TRUE FALSE FALSE FALSE FALSE
CMC8539
Message The CMC
arg1
is unable to log
arg2
event to the Hardware Log.
Arguments
arg1 =
slot id
arg2 =
event message
Detailed
Description
CMC cannot log new events to Hardware Log if Hardware Log is full. Therefore, new events
are not written to the log unless older events are cleared. This issue also occurs if event
logging is disabled.
Recommended
Response Action
Do the following: 1) Save the Hardware Log if required. 2) Clear the Hardware Log.
Category Audit
SubCategory CMC = Chassis Management Controller
Severity Severity 3 (Informational)
Trap/EventID FALSE
LCD Message No LCD message display defined.
Initial Default. LC Log
122