Messages Reference Guide

Detailed
Description
CMC is unable to obtain the link tuning information for the newly installed hardware (server,
Input Output Module, or Mezzanine card), or is unable to send the link tuning information to
iDRAC.
Recommended
Response Action
Make sure that the currently installed CMC firmware is the latest. Otherwise, update the CMC
with the latest CMC firmware and retry the operation.
Category System Health
SubCategory CMC = Chassis Management Controller
Severity Severity 2 (Warning)
Trap/EventID 2546
LCD Message No LCD message display defined.
Initial Default. SNMP Alert;#EMAIL Alert;#LC Log;#Remote System Log
Filter
Visibility
IPMI Alert SNMP
Alert
Email
Alert
LC Log LCD Power Off Power
Cycle
Reset
TRUE FALSE TRUE TRUE TRUE FALSE FALSE FALSE FALSE
CMC8529
Message Unable to perform the requested action on the server-
arg1
, because of insufficient privileges.
Arguments
arg1 =
slot number
Detailed
Description
The user account does not have sufficient privileges to perform the requested operation.
Server Administrator privilege is required to perform the requested action.
Recommended
Response Action
Use a different user account that has Server Administrator privilege, and retry the operation.
For more information, contact your system administrator or service provider.
Category Audit
SubCategory CMC = Chassis Management Controller
Severity Severity 2 (Warning)
Trap/EventID FALSE
LCD Message No LCD message display defined.
Initial Default. LC Log
Filter
Visibility
IPMI Alert SNMP
Alert
Email
Alert
LC Log LCD Power Off Power
Cycle
Reset
FALSE FALSE FALSE FALSE TRUE FALSE FALSE FALSE FALSE
CMC8531
Message Unable to perform the requested action on the sleeve
arg1
because of insufficient user
privileges.
119