Messages Reference Guide
Detailed
Description
FRU on the server specified in the message is not functioning or CMC is unable to read it.
Recommended
Response Action
Do the following: 1) Reset iDRAC of the specified server or virtual reseat the server. 2) Reset
CMC and wait for a few minutes. If the issue persists, contact your service provider.
Category System Health
SubCategory CMC = Chassis Management Controller
Severity Severity 1 (Critical)
Trap/EventID 2545
LCD Message No LCD message display defined.
Initial Default. SNMP Alert;#EMAIL Alert;#LC Log;#Remote System Log
Filter
Visibility
IPMI Alert SNMP
Alert
Email
Alert
LC Log LCD Power Off Power
Cycle
Reset
TRUE FALSE TRUE TRUE TRUE FALSE FALSE FALSE FALSE
CMC8521
Message The Mezz card 1 FRU for the server
arg1
is not functioning.
Arguments
•
arg1 =
slot number
Detailed
Description
The Mezz card 1 FRU for the server specified in the message is not functioning or CMC is
unable to read it.
Recommended
Response Action
Do the following: 1) Reset iDRAC of the specified server or virtual reseat the server. 2) Reset
CMC and wait for a few minutes. If the issue persists, contact your service provider.
Category System Health
SubCategory CMC = Chassis Management Controller
Severity Severity 1 (Critical)
Trap/EventID 2545
LCD Message No LCD message display defined.
Initial Default. SNMP Alert;#EMAIL Alert;#LC Log;#Remote System Log
Filter
Visibility
IPMI Alert SNMP
Alert
Email
Alert
LC Log LCD Power Off Power
Cycle
Reset
TRUE FALSE TRUE TRUE TRUE FALSE FALSE FALSE FALSE
CMC8522
Message The Mezz card 2 FRU for the server
arg1
is not functioning.
Arguments
•
arg1 =
slot number
115