Messages Reference Guide

SubCategory CMC = Chassis Management Controller
Severity Severity 2 (Warning)
Trap/EventID 2546
LCD Message No LCD message display defined.
Initial Default. SNMP Alert;#EMAIL Alert;#LC Log;#Remote System Log
Filter
Visibility
IPMI Alert SNMP
Alert
Email
Alert
LC Log LCD Power Off Power
Cycle
Reset
TRUE FALSE TRUE TRUE TRUE FALSE FALSE FALSE FALSE
CMC8517
Message A double height server is detected in slot
arg1
, however the server is not detected in the bottom
slot.
Arguments
arg1 =
slot number
Detailed
Description
A double height server is detected in slot specified in the message, however the server is not
detected in the bottom slot. This occurs if the server is not correctly inserted into the chassis.
Recommended
Response Action
Remove the server from the chassis, check for any broken or bent pins at the rear of the
server. If there is no damage, reinsert the server into the chassis.
Category System Health
SubCategory CMC = Chassis Management Controller
Severity Severity 1 (Critical)
Trap/EventID 2545
LCD Message No LCD message display defined.
Initial Default. SNMP Alert;#EMAIL Alert;#LC Log;#Remote System Log
Filter
Visibility
IPMI Alert SNMP
Alert
Email
Alert
LC Log LCD Power Off Power
Cycle
Reset
TRUE FALSE TRUE TRUE TRUE FALSE FALSE FALSE FALSE
CMC8518
Message Detecting Double height server in slot
arg1
but the iDRAC in bottom slot
arg2
is also responding.
Arguments
arg1 =
slot number
arg2 =
slot number
Detailed
Description
the Double height server identified in the message is detected in the top slot. However, the
bottom slot is also responding which should not occur if a double height server is inserted.
113