Messages Reference Guide

SubCategory CMC = Chassis Management Controller
Severity Severity 3 (Informational)
Trap/EventID FALSE
LCD Message No LCD message display defined.
Initial Default. LC Log
Filter
Visibility
IPMI Alert SNMP
Alert
Email
Alert
LC Log LCD Power Off Power
Cycle
Reset
FALSE FALSE FALSE FALSE TRUE FALSE FALSE FALSE FALSE
CMC8507
Message Extended Storage for primary CMC and secondary CMC synchronization is complete.
Detailed
Description
The Extended Storage feature synchronizes data from the primary CMC removable flash media
SD Card is synchronized with the secondary CMC removable flash media SD Card.
Recommended
Response Action
No response action required.
Category Audit
SubCategory CMC = Chassis Management Controller
Severity Severity 3 (Informational)
Trap/EventID 8691
LCD Message No LCD message display defined.
Initial Default. SNMP Alert;#EMAIL Alert;#LC Log;#Remote System Log
Filter
Visibility
IPMI Alert SNMP
Alert
Email
Alert
LC Log LCD Power Off Power
Cycle
Reset
TRUE FALSE TRUE TRUE TRUE FALSE FALSE FALSE FALSE
CMC8508
Message Unable to synchronize the primary and secondary CMC removable flash media and the
Extended Storage feature is not available.
Detailed
Description
The Extended Storage feature is not activated if the removable flash media SD Card on the
secondary CMC is not functioning properly.
Recommended
Response Action
Do the following and retry the operation: 1) In the CMC Web interface, go to Chassis Controller
> Flash Media > Configuration, and verify if the SD card on secondary CMC displays errors. 2) If
errors are displayed, execute the following racadm command: "racadm cmcchangover". 3)
Repair the removable flash media SD Card by selecting the Chassis Controller > Flash Media >
Configuration > Repair Active Controller Media in the CMC Web interface. Repairing is only
allowed on the SD card of the primary CMC. If the problem persists, replace the card.
Category Audit
108