Messages Reference Guide

Initial Default. LC Log
Filter
Visibility
IPMI Alert SNMP
Alert
Email
Alert
LC Log LCD Power Off Power
Cycle
Reset
FALSE FALSE FALSE FALSE TRUE FALSE FALSE FALSE FALSE
CMC8503
Message Unable to access the IPv4 information of the server.
Detailed
Description
CMC is unable to access the IPv4 information for the specified server. Unable to display the
specified servers Launch iDRAC link on the CMC Web interface.
Recommended
Response Action
Enable IPv4 on the specified slots iDRAC via the CMC command line or Web GUI interface, for
the iDRACs launch point to show up on the CMC web GUI. For the command line options or
navigation for Web intereface, see the Trobleshooting section in the CMC Users Guide.
Category System Health
SubCategory CMC = Chassis Management Controller
Severity Severity 1 (Critical)
Trap/EventID FALSE
LCD Message No LCD message display defined.
Initial Default. LC Log
Filter
Visibility
IPMI Alert SNMP
Alert
Email
Alert
LC Log LCD Power Off Power
Cycle
Reset
FALSE FALSE FALSE FALSE TRUE FALSE FALSE FALSE FALSE
CMC8504
Message Unable to access server:
arg1
, because the NIC is disabled on the identified server.
Arguments
arg1 =
slot number
Detailed
Description
The NIC is disabled on the server identified in the message, and the CMC is unable to display
the link to launch the iDRAC web interface.
Recommended
Response Action
Enable the NIC on the server identified in the message using the CMC command line or CMC
Web interface, so that the link to launch iDRAC is displayed on the CMC Web interface. To
enable the NIC for DHCP using RACADM, enter "racadm setniccfg -m server-<slot number> -d"
where <slot number> is the server identifed in the message. To enable the NIC using the Web
interface, click Server Overview > select the identified server, go to Setup > select the Enable
LAN check box.
Category System Health
SubCategory CMC = Chassis Management Controller
Severity Severity 3 (Informational)