Command Line Reference Guide
• –size: <VD size>: The size of the VD.
• b: Specify the size in bytes.
• k: Specify the size in kilobytes.
• m: Specify the size in megabytes.
• g: Specify the size in gigabytes.
• t: Specify the size in terabytes.
• -cc: Create a CacheCade or Enhanced Cache VD.
Example
racadm raid createvd:RAID.ChassisIntegrated.1-1 -rl r0 -
pdkey:Disk.Bay.0:Enclosure.Internal.0-0:RAID.ChassisIntegrated.1-1
deletevd
Description
Deletes the specified virtual drive.
Synopsis
racadm raid deletevd:<VD FQDD> {-current|-pending}
Input
• –current <optional>: Performs the configuration right now.
NOTE: If this requires the system to reboot, it will reboot.
• –pending: Save the configuration change for a later application. You can use a combination
of the –pending and –current flags on multiple commands to reduce the possible number of
system reboots.
Example
racadm raid deletevd:Disk.Virtual.0:RAID.ChassisIntegrated.1-1
discardcache
Description
Discards any pinned or persistent cache present on the RAID controller.
Synopsis
racadm raid discardcache:<Controller FQDD> {-current | -pending}
Input
• –current <optional>: Performs the configuration right now.
NOTE: If this requires the system to reboot, the system is rebooted.
• –pending: Save the configuration change for a later application. You can use a combination
of the –pending and –current flags on multiple commands to reduce the possible number of
system reboots.
Example
racadm raid discardcache:RAID.ChassisIntegrated.1-1
The syntax of the command specified is not correct.
The syntax of the command specified is not correct.
exportlog
Description
Export a log from the device.
Synopsis
racadm raid exportlog:<FQDD> -l<CIFS or NFS share> -u<username> -
p <password> [-f <filename>]
72