Reference Guide
Recommended
Response Action
1) Review system logs for power supply exceptions. 2) Reseat the memory module. 3) If the
problem persists, contact technical support. Refer to the product documentation to choose a
convenient contact method.
Category System Health
SubCategory VLT = Voltage
Severity Severity 1 (Critical)
Trap/EventID FALSE
LCD Message Memory module <name> voltage is outside of range. Contact support
Initial Default. FALSE
Filter
Visibility
IPMI Alert SNMP
Alert
Email
Alert
LC Log LCD Power Off Power
Cycle
Reset
FALSE FALSE FALSE FALSE FALSE FALSE FALSE FALSE FALSE
VLT0229
Message The memory module
arg1
voltage is within range.
Arguments
•
arg1 =
name
Detailed
Description
None
Recommended
Response Action
No response action is required.
Category System Health
SubCategory VLT = Voltage
Severity Severity 3 (Informational)
Trap/EventID FALSE
LCD Message No LCD message display defined.
Initial Default. FALSE
Filter
Visibility
IPMI Alert SNMP
Alert
Email
Alert
LC Log LCD Power Off Power
Cycle
Reset
FALSE FALSE FALSE FALSE FALSE FALSE FALSE FALSE FALSE
VLT0230
Message The mezzanine card
arg1arg2
voltage is less than the lower warning threshold.
Arguments
•
arg1 =
number
•
arg2 =
name
927