Reference Guide
LCD Message No LCD message display defined.
Initial Default. LC Log
Filter
Visibility
IPMI Alert SNMP
Alert
Email
Alert
LC Log LCD Power Off Power
Cycle
Reset
TRUE FALSE TRUE TRUE TRUE FALSE FALSE FALSE FALSE
VLT0203
Message The system board
arg1
voltage is greater than the upper critical threshold.
Arguments
•
arg1 =
name
Detailed
Description
System hardware detected an over voltage or under voltage condition. If multiple voltage
exceptions occur consecutively the system may power down in failsafe mode.
Recommended
Response Action
1) Review system logs for power supply exceptions 2) Reduce system to minimum
configuration, inspect and re-install system cables. 3) If the problem persists, contact technical
support. Refer to the product documentation to choose a convenient contact method.
Category System Health
SubCategory VLT = Voltage
Severity Severity 1 (Critical)
Trap/EventID 2169
LCD Message The system board <name> voltage is outside of range. Contact support
Initial Default. LC Log
Filter
Visibility
IPMI Alert SNMP
Alert
Email
Alert
LC Log LCD Power Off Power
Cycle
Reset
TRUE FALSE TRUE TRUE TRUE FALSE FALSE FALSE FALSE
VLT0204
Message The system board
arg1
voltage is outside of range.
Arguments
•
arg1 =
name
Detailed
Description
System hardware detected an over voltage or under voltage condition. If multiple voltage
exceptions occur consecutively the system may power down in failsafe mode.
Recommended
Response Action
1) Review system logs for power supply exceptions 2) Reduce system to minimum
configuration, inspect and re-install system cables. 3) If the problem persists, contact technical
support. Refer to the product documentation to choose a convenient contact method.
Category System Health
SubCategory VLT = Voltage
910