Reference Guide
SubCategory BAT = Battery Event
Severity Severity 3 (Informational)
Trap/EventID FALSE
LCD Message No LCD message display defined.
Initial Default. FALSE
Filter
Visibility
IPMI Alert SNMP
Alert
Email
Alert
LC Log LCD Power Off Power
Cycle
Reset
FALSE FALSE FALSE FALSE FALSE FALSE FALSE FALSE FALSE
BAT0012
Message The storage battery for disk drive bay
arg1
has failed.
Arguments
•
arg1 =
bay
Detailed
Description
The PERC RAID controller battery may have failed because of thermal exceptions.
Recommended
Response Action
1) Verify the PERC RAID controller battery installation for the associated bay. 2) Check the
system logs for thermal related issues.
Category System Health
SubCategory BAT = Battery Event
Severity Severity 1 (Critical)
Trap/EventID FALSE
LCD Message Battery for disk drive bay <bay> has failed. Check battery.
Initial Default. FALSE
Filter
Visibility
IPMI Alert SNMP
Alert
Email
Alert
LC Log LCD Power Off Power
Cycle
Reset
FALSE FALSE FALSE FALSE FALSE FALSE FALSE FALSE FALSE
BAT0013
Message The storage battery for disk drive bay
arg1
is present.
Arguments
•
arg1 =
bay
Detailed
Description
None
Recommended
Response Action
No response action is required.