Reference Guide

Recommended
Response Action
Replace the failed or corrupt disk. You can identify a disk that has failed by locating the disk
that has a red "X" for its status. Restart the virtual disk rebuild.
Category Storage
SubCategory VDR = Virtual Disk
Severity Severity 1 (Critical)
Trap/EventID 4353
LCD Message No LCD message display defined.
Initial Default. SNMP Alert;#LCD;#Remote System Log
Filter
Visibility
IPMI Alert SNMP
Alert
Email
Alert
LC Log LCD Power Off Power
Cycle
Reset
TRUE FALSE TRUE TRUE TRUE TRUE FALSE FALSE FALSE
VDR21
Message Consistency check for
arg1
has completed.
Arguments
arg1 =
virtual disk
Detailed
Description
This message is generated after a consistency check completes on a virtual disk.
Recommended
Response Action
No response action is required.
Category Storage
SubCategory VDR = Virtual Disk
Severity Severity 3 (Informational)
Trap/EventID 4355
LCD Message No LCD message display defined.
Initial Default. SNMP Alert;#LCD;#Remote System Log
Filter
Visibility
IPMI Alert SNMP
Alert
Email
Alert
LC Log LCD Power Off Power
Cycle
Reset
TRUE FALSE TRUE TRUE TRUE TRUE FALSE FALSE FALSE
VDR22
Message Formatting the
arg1
is completed.
Arguments
arg1 =
VD Name
868