Reference Guide
Detailed
Description
Ambient air temperature is too warm or one or more fans may have failed.
Recommended
Response Action
Check system operating environment and review event log for fan failures.
Category System Health
SubCategory TMP = Temperature
Severity Severity 2 (Warning)
Trap/EventID 2162
LCD Message No LCD message display defined.
Initial Default. LC Log
Filter
Visibility
IPMI Alert SNMP
Alert
Email
Alert
LC Log LCD Power Off Power
Cycle
Reset
TRUE FALSE TRUE TRUE TRUE FALSE FALSE FALSE FALSE
TMP0115
Message The
arg1
temperature is greater than the upper critical threshold.
Arguments
•
arg1 =
name
Detailed
Description
Ambient air temperature is too warm or one or more fans may have failed.
Recommended
Response Action
Check system operating environment and review event log for fan failures.
Category System Health
SubCategory TMP = Temperature
Severity Severity 1 (Critical)
Trap/EventID 2161
LCD Message The <name> temperature is outside of range . Check Fans
Initial Default. LC Log
Filter
Visibility
IPMI Alert SNMP
Alert
Email
Alert
LC Log LCD Power Off Power
Cycle
Reset
TRUE FALSE TRUE TRUE TRUE FALSE FALSE FALSE FALSE
TMP0116
Message The
arg1
temperature is outside of range.
Arguments
•
arg1 =
name