Reference Guide

Category System Health
SubCategory TMP = Temperature
Severity Severity 2 (Warning)
Trap/EventID FALSE
LCD Message No LCD message display defined.
Initial Default. FALSE
Filter
Visibility
IPMI Alert SNMP
Alert
Email
Alert
LC Log LCD Power Off Power
Cycle
Reset
FALSE FALSE FALSE FALSE FALSE FALSE FALSE FALSE FALSE
TMP0107
Message The memory module
arg1
temperature is less than the lower critical threshold.
Arguments
arg1 =
number
Detailed
Description
Ambient air temperature is too cool.
Recommended
Response Action
Check system operating environment.
Category System Health
SubCategory TMP = Temperature
Severity Severity 1 (Critical)
Trap/EventID FALSE
LCD Message Memory module <number> temperature is outside of range. Check Fans
Initial Default. FALSE
Filter
Visibility
IPMI Alert SNMP
Alert
Email
Alert
LC Log LCD Power Off Power
Cycle
Reset
FALSE FALSE FALSE FALSE FALSE FALSE FALSE FALSE FALSE
TMP0108
Message The memory module
arg1
temperature is greater than the upper warning threshold.
Arguments
arg1 =
number
Detailed
Description
Ambient air temperature is too warm or one or more fans may have failed.
831