Reference Guide

Severity Severity 2 (Warning)
Trap/EventID FALSE
LCD Message No LCD message display defined.
Initial Default. LC Log
Filter
Visibility
IPMI Alert SNMP
Alert
Email
Alert
LC Log LCD Power Off Power
Cycle
Reset
FALSE FALSE FALSE FALSE TRUE FALSE FALSE FALSE FALSE
TMP8502
Message Able to read planar board temperature sensors. Cooling set for normal chassis operation.
Detailed
Description
The system has recovered from being unable to read planar board or control panel
temperature sensors.
Recommended
Response Action
No response action required.
Category Audit
SubCategory TMP = Temperature
Severity Severity 3 (Informational)
Trap/EventID FALSE
LCD Message No LCD message display defined.
Initial Default. LC Log
Filter
Visibility
IPMI Alert SNMP
Alert
Email
Alert
LC Log LCD Power Off Power
Cycle
Reset
FALSE FALSE FALSE FALSE TRUE FALSE FALSE FALSE FALSE
TMP1000
Message
arg1
exceeded the maximum warning threshold.
Arguments
arg1 =
tempsensor name
Detailed
Description
The enclosure is too hot. A variety of factors can cause the excessive temperature. For
example, a fan may have failed, the thermostat may be set too high, or the room temperature
may be too hot.
Recommended
Response Action
Check for factors that may cause overheating. For example, verify that the enclosure fan is
working. You should check the thermostat settings and examine whether the enclosure is
located near a heat source. Make sure the enclosure has enough ventilation and that the room
temperature is not too hot. Refer to the enclosure documentation for more diagnostic
information.
820