Reference Guide
Recommended
Response Action
No response action is required.
Category Storage
SubCategory BAT = Battery Event
Severity Severity 3 (Informational)
Trap/EventID 4275
LCD Message No LCD message display defined.
Initial Default. SNMP Alert;#LCD;#Remote System Log
Filter
Visibility
IPMI Alert SNMP
Alert
Email
Alert
LC Log LCD Power Off Power
Cycle
Reset
TRUE FALSE TRUE TRUE TRUE TRUE FALSE FALSE FALSE
BAT1018
Message Battery on
arg1
is degraded.
Arguments
•
arg1 =
Controller name
Detailed
Description
The temperature of the battery is high. This may be due to the battery being charged.
Recommended
Response Action
If the battery is being charged, then charging the battery should be stopped until the battery
cools down and charging should be resumed. If this is not case, then some other condition
exists and should be investigated.
Category Storage
SubCategory BAT = Battery Event
Severity Severity 2 (Warning)
Trap/EventID 4274
LCD Message No LCD message display defined.
Initial Default. SNMP Alert;#LCD;#Remote System Log
Filter
Visibility
IPMI Alert SNMP
Alert
Email
Alert
LC Log LCD Power Off Power
Cycle
Reset
TRUE FALSE TRUE TRUE TRUE TRUE FALSE FALSE FALSE
BAT1019
Message Battery on
arg1
is charging.
Arguments
•
arg1 =
Controller name
80