Reference Guide

Detailed
Description
The Chassis Management Controller is unable to set the administrator role for the iDRAC root
user. This can happen if the communction to the iDRAC from CMC is non-functional or iDRAC is
rebooting.
Recommended
Response Action
If communications with the iDRAC is not functioning, reset the iDRAC and retry the operation
after a few minutes. Run the RACADM command "racadm ping server-<slot number> " to check
the communications. If the communications are not functional, restart the iDRAC by performing
a Virtual Reseat of the server using the RACADM command "racadm racreset -m server-<slot
id>".
Category Audit
SubCategory SWC = Software Config
Severity Severity 3 (Informational)
Trap/EventID FALSE
LCD Message No LCD message display defined.
Initial Default. LC Log
Filter
Visibility
IPMI Alert SNMP
Alert
Email
Alert
LC Log LCD Power Off Power
Cycle
Reset
FALSE FALSE FALSE FALSE TRUE FALSE FALSE FALSE FALSE
SWC8532
Message Chassis Management Controller is unable to set chassis assigned QuickDeploly IP addresses
because the starting IP address cannot accomodate all iDRACs.
Detailed
Description
The starting IP address specified cannot accommodate all the servers. The starting iDRAC IPv4
Address specifies the static IPv4 address of the iDRAC located in the first slot. The static IPv4
address of each subsequent iDRAC is calculated as a slot number increment of this IPv4
address.
Recommended
Response Action
Make sure there are enough IPv4 addresses for all the iDRACs and then retry the operation.
Category Audit
SubCategory SWC = Software Config
Severity Severity 3 (Informational)
Trap/EventID FALSE
LCD Message No LCD message display defined.
Initial Default. LC Log
Filter
Visibility
IPMI Alert SNMP
Alert
Email
Alert
LC Log LCD Power Off Power
Cycle
Reset
FALSE FALSE FALSE FALSE TRUE FALSE FALSE FALSE FALSE
774