Reference Guide

Filter
Visibility
IPMI Alert SNMP
Alert
Email
Alert
LC Log LCD Power Off Power
Cycle
Reset
FALSE FALSE FALSE FALSE TRUE FALSE FALSE FALSE FALSE
SWC8522
Message Chassis Group Leader update of member
arg1
configuration successful.
Arguments
arg1 =
member id
Detailed
Description
Successfully completed a configuration sync with the member identified in the message.
Recommended
Response Action
No response action required.
Category Audit
SubCategory SWC = Software Config
Severity Severity 3 (Informational)
Trap/EventID FALSE
LCD Message No LCD message display defined.
Initial Default. LC Log
Filter
Visibility
IPMI Alert SNMP
Alert
Email
Alert
LC Log LCD Power Off Power
Cycle
Reset
FALSE FALSE FALSE FALSE TRUE FALSE FALSE FALSE FALSE
SWC8523
Message Unable to complete Chassis Group Leader update of member
arg1
.
Arguments
arg1 =
DNS or IP address
Detailed
Description
Unable to complete a configuration sync with the member identified in the message.
Recommended
Response Action
Check the communications between the Chassis Group Leader and the member. Run the
RACADM command "racadm ping <DNS or IP address> " to check the communications. If the
communications are not functional, resolve the communications issue. If the communications
are functional, remove the member from the group and re-add the member. If the issue
persists, contact your service provider.
Category Audit
SubCategory SWC = Software Config
Severity Severity 1 (Critical)